Our Industrial Process Controls are designed for frequent ON/OFF events that are required in industrial and agricultural applications. The control's time interval and number of loads may vary by applicatin. Industrial Process Controls ... the control you want when your schedule is constant. Industry firstBuilt to Last Our electromechanical Industrial Process Controls are equipped with durable and reliable sealed synchronous motors.
 
EJW ... OUR LATEST INDUSTRIAL PROCESS CONTROL
 

Paragon has taken the popular JW one step further. Our new exclusive EJW time control is an accurate and reliable electronic time control with the look and feel of analog technology. The EJW gives you the equivalent of 32 JW controls in just 1 unit.

You get more flexibility with 32 time durations and with the ability to accommodate both 120-240 volts in a single unit. The display dials are set like volume controls on a radio. The left dial selects time durations ranging from 15 seconds to 24 hours. The right dial indicates the percentage for ON and OFF times during a givn duratin. You can choose the format that's best for your schedule and your application.

The EJW comes in a NEMA 4X enclosure suitable for both indoor and outdoor use. This enclosure protects against falling dirt, rain, sleet, snow, windblown dust, splashing water , hose-directed water, corrosion, and ice.

 

EJW-M      EJW-M
EJW     EJW

• 1 SPST relay
• On time adjustable from 1% to 99% of full-scale dial for a wide range of ON/OFF combinations
Paragon exclusive • Only control available in NEMA 4X
• User can easily adjust set ON/OFF percentage
• Time intervals can be set from 15 seconds to 24 hours
• Duty cydling capable when used with our 4000 series
• EJW unit dimensions are 4-3/4"W x 4-3/4"H x 3"D
• EJW-M unit dimensions are 4-3/4"W x 4-3/4"H x 1"D

[DOWNLOAD/PRINT EJW SERIES SELL SHEET IN PDF]

 
 
JW

• 1 SPST relay
• ON time adjustable from 2% to 90% of full-scale dial for a wide range of ON/OFF combinations
• User can easily adjust set ON/OFF percentage
• Time intervals can be set from several seconds to 60 minutes in
5-minute,10-minute and 60-minute increments
• 4 dial ranges with varied timing options for diverse applications
• Duty cycling capable when used with our 4000 series
• Available in NEMA 1 drawn steel and NEMA 3R non-metallic enclosure with clear-view cover for indoor and outdoor use
• NEMA 1 unit dimensions are 3-1/2” W x 5-1/8” H x 2-7/8” D
• NEMA 3R unit dimensions are 6-1/2” W x 9” H x 3-7/8” D

[VIEW SPECIFICATION & MANUAL]

 

1015

• 1 SPDT relay
• Up to 48 ON/OFF events per day
• Quick schedule adjustments can be made with 96 self-contained trippers
• Time intervals can be set between 15 minutes and 23-3/4 hours
Industry first • Paragon-developed Skip-A-Day feature allows units to be programmed to skip 1 to 7 days without disturbing set program
Industry first • Wiping contact blades maintain a consistent contact surface for extended clock life
• Available in NEMA 3 metal enclosure for indoor and outdoor use
• Unit dimensions are 5-3/8” W x 9-5/8” H x 4-3/16” D

[VIEW SPECIFICATION & MANUAL]

8025

• 2 NO-1 NC relay
• Up to 12 ON/OFF events per day with a minimum of 2 hours between operations
• Time increments can be set between 60 seconds to 27-1/2 minutes
• Multi-pole clock enables timer to run multiple electrical loads simultaneously
Industry first • Wiping contact blades maintain a consistent contact surface to reduce wear and tear
• Extended clock life with sealed motor and wiping contact blades
• Available in NEMA 1 drawn steel and NEMA 3R non-metallic enclosure for indoor and outdoor use
• NEMA 1 unit dimensions are 4-3/8” W x 7-11/16” H x 3-13/16” D
• NEMA 3R unit dimensions are 6-1/2” W x 9” H x 3-7/8” D

[VIEW SPECIFICATION]

 

42000

• 1 SPST or DPST relay
• Up to 48 ON/OFF events per day
• Time increments can be set from 15 minutes to 23-3/4 hours
Industry first • Sealed motor and wiping contact blades for longer clock life
• Available in NEMA 3 non-metallic enclosure for outdoor use
• Clutched clock dial for easy monitoring of program
• Unit dimensions are 5-3/8” W x 9-5/8” H x 4-3/16” D

[VIEW SPECIFICATION & MANUAL]

44000

• 1SPST or SPDT switch
• 1 to 7 ON/OFF events every 4 hours
• Time intervals can be set from 15 minutes to 3-3/4 hours
• Manual override lever temporarily reverses switch operation without permanently affecting set schedule
• Sealed motor and wiping contact blades for longer clock life
• Available in NEMA 1 drawn steel enclosure for indoor use
• Unit dimensions are 4-1/16” W x 7-7/8” H x 2-15/16” D

[VIEW 44001 MANUAL]
[VIEW 44005 MANUAL]

TECHNICAL INFORMATION

How to Specify

Installer shall furnish and install . . .

EJW with 1 SPST
JW with 1 SPST
1015-00, 1015-40 with 1 SPST
8025 with 2 No-1 NC
42011-00, 42011-20 with 1 SPST
42013-00, 42013-20 with 1 SPST
44001-00 with 1 SPST
44005-00 with 1 SPST

Timekeeping Capabilities

The control shall be utilized as 24-hour process controls and/or industrial process controls.

Programming Attributes and Capabilities

Events/Set Points
The control shall provide for . . .

1 event repeatable (JW)
48 events in 15-minute intervals (1015 series, 42000 series)
12 events with a minimum of 2 hours (8025 series)
1 to 7 events every 4 hours 
(44000 series)

Holidays

Control shall have Skip-A-Day feature (1015 series)

 

Override
The control shall provide . . .

Manual override (44000 series)

Hardware Attributes

Display
The clock format shall be a dial range from 5 minutes to 60 minutes (JW series), 4-hour dial (44000 series) and shall be a 24-hour (42000 series, 8025 series, 1015 series) dial indicating hour of the day with notations for night and evening hours.

Interface
N/A

Enclosure*
Control shall be housed in a . . .

NEMA 3R non-metallic enclosure with clear-view cover (JWPC series)
NEMA 1 steel or NEMA 3R non-metallic enclosure with clear-view cover (8025 series)
NEMA 3 steel lockable tamper resistant enclosure (1015 series, 42000 series)
NEMA 1 steel (44000 series)
NEMA 4X non-metallic enclosure (EJW)


*See product comparison table for specific variations.



Model No. Switch
Type
Hp Amp Wiring
Diag.#
AC Line Graduation Range Enclosure Material Enclosure
Type
Dimensions Shipping Wgt.
Volts W H D Lb. Kg.
PROCESS CONTROLS - JW SERIES
EJW** SPST 1 20 38 120-240 various 15 sec.-24hrs. Non-metallic  (indoor/outdoor) NEMA 4X 4-3/4" 4-3/4" 3" 1 0.4
EJW-M** SPST 2 20 38 120-240 various 15 sec.-24hrs. Mechanism only - 4-3/4" 4-3/4" 1" 1/2 0.2
JW5-00 SPST 1/2 15 39, 40 120 10 seconds 5 minutes Metal (indoor) NEMA 1 3-1/2" 5-1/8" 2-7/8" 1-1/4 0.6
JW5-00PC SPST 1/2 15 39, 40 120 10 seconds 5 minutes Non-metallic with clear-view cover (indoor/outdoor) NEMA 3R 6-1/2" 9" 3-7/8" 2 0.9
JW5-20* SPST 1/2 15 39, 40 208-240 10 seconds 5 minutes Metal (indoor) NEMA 1 3-1/2" 5-1/8" 2-7/8" 1-1/4 0.6
JW5-20PC* SPST 1/2 15 39, 40 208-240 10 seconds 5 minutes Non-metallic with clear-view cover (indoor/outdoor) NEMA 3R 6-1/2" 9" 3-7/8" 2 0.9
JW10-00 SPST 1/2 15 39, 40 120 12 seconds 10 minutes Metal (indoor) NEMA 1 3-1/2" 5-1/8" 2-7/8" 1-1/4 0.6
JW10-00PC SPST 1/2 15 39, 40 120 12 seconds 10 minutes Non-metallic with clear-view cover (indoor/outdoor) NEMA 3R 6-1/2" 9" 3-7/8" 2 0.9
JW10-20* SPST 1/2 15 39, 40 208-240 12 seconds 10 minutes Metal (indoor) NEMA 1 3-1/2" 5-1/8" 2-7/8" 1-1/4 0.6
JW10-20PC* SPST 1/2 15 39, 40 208-240 12 seconds 10 minutes Non-metallic with clear-view cover (indoor/outdoor) NEMA 3R 6-1/2" 9" 3-7/8" 2 0.9
JW30-00 SPST 1/2 15 39, 40 120 30 seconds 30 minutes Metal (indoor) NEMA 1 3-1/2" 5-1/8" 2-7/8" 1-1/4 0.6
JW30-00PC SPST 1/2 15 39, 40 120 30 seconds 30 minutes Non-metallic with clear-view cover (indoor/outdoor) NEMA 3R 6-1/2" 9" 2-7/8" 2 0.9
JW30-20* SPST 1/2 15 39, 40 208-240 30 seconds 30 minutes Metal (indoor) NEMA 1 3-1/2" 5-1/8" 2-7/8" 1-1/4 0.6
JW30-20PC* SPST 1/2 15 39, 40 208-240 30 seconds 30 minutes Non-metallic with clear-view cover (indoor/outdoor) NEMA 3R 6-1/2" 9" 3-7/8" 2 0.9
JW60-00 SPST 1/2 15 39, 40 120 60 seconds 60 minutes Metal (indoor) NEMA 1 3-1/2" 5-1/8" 2-7/8" 1-1/4 0.6
JW60-00PC SPST 1/2 15 39, 40 120 60 seconds 60 minutes Non-metallic with clear-view cover (indoor/outdoor) NEMA 3R 6-1/2" 9" 3-7/8" 2 0.9
JW60-20* SPST 1/2 15 39, 40 208-240 60 seconds 60 minutes Metal (indoor) NEMA 1 3-1/2" 5-1/8" 2-7/8" 1-1/4 0.6
JW60-20PC* SPST 1/2 15 39, 40 208-240 60 seconds 60 minutes Non-metallic with clear-view cover (indoor/outdoor) NEMA 3R 6-1/2" 9" 3-7/8" 2 0.9

*Not UL or CSA listed
** No-20amp, NC-10amp

Model No. Switch
Type
Hp Amp Wiring
Diag.#
AC Line Enclosure Material Enclosure
Type
Type of Mount Dimensions Shipping Wgt.
Volts W H D Lb. Kg.
PROCESS CONTROLS - 1015 SERIES
1015-00RS SPDT - 10 30, 31, 32 120,208-240 Metal (indoor/outdoor) NEMA 3 Enclosure mount 5-3/8" 9-5/8" 4-3/16" 9 4.1
1015-40TS SPDT - 5 30, 31, 32 480 Metal (indoor/outdoor) NEMA 3 Enclosure mount 5-3/8" 9-5/8" 4-3/16" 9 4.1

PROCESS CONTROLS - 8025 SERIES

8025-00 2NO-1NC 2 40 35 120 Metal (indoor) NEMA 1 Enclosure mount 4-3/8" 7-11/16'' 3-13/16" 3-1/2 1.6
8025-00P 2NO-1NC 2 40 35 120 Non-metallic with clear-view cover (indoor/outdoor) NEMA 3R Enclosure mount 6-1/2" 9" 3-7/8" 4 1.8
8025-20 2NO-1NC 2 40 35 208-240 Metal (indoor) NEMA 1 Enclosure mount 4-3/8" 7-11/16" 3-13/16" 3-1/2 1.6

PROCESS CONTROLS - 42000 SERIES

40211-00 SPST 1 15 33, 34 120 Metal (indoor/outdoor) NEMA 3 Enclosure mount 5-3/8" 9-5/8" 4-3/16" 7 3.2
40211-20 SPST 1 10 33, 34 208-240 Metal (indoor/outdoor) NEMA 3 Enclosure mount 5-3/8" 9-5/8" 4-3/16" 7 3.2
40213-00 DPST 1 15 33, 34 120 Metal (indoor/outdoor) NEMA 3 Enclosure mount 5-3/8" 9-5/8" 4-3/16" 7 3.2
40213-20 DPST 2 20 33, 34 208-240 Metal (indoor/outdoor) NEMA 3 Enclosure mount 5-3/8" 9-5/8" 4-3/16" 7 3.2

PROCESS CONTROLS - 44000 SERIES

44001-00 SPST 1 40 24, 25 120 Metal (indoor) NEMA 1 Enclosure mount 4-1/16" 7-7/8" 2-15/16" 2-1/2 1.1
44005-00 SPDT 1 40 24, 25 120 Metal (indoor) NEMA 1 Enclosure mount 4-1/16" 7-7/8" 2-15/16" 2-1/2 1.1

Models with suffix “P” are sold in NEMA 3R non-metallic enclosure