FAQ Search
Distributor Locator
Careers
Employee Login
|

|
FEATURES AND SPECIFICATION GUIDE
SECTION
1
- Quads
- Tri-Timers
- Double Duty Clocks
|
SECTION
2
- 24-Hour Timers
- 24-Hour Process Controls
- AstroDial
|
|
24-Hour
Timers |
24-Hour
Process Controls |
AstroDial |
| PROGRAMMING |
EC4000 |
P100 |
4000 |
EC11D |
WB101 |
42000 |
1015 |
8025 |
EC365DST1 |
EC365DST2 |
| 24-Hour
Control |
w/
skip |
w/
skip |
• |
w/
skip |
• |
• |
w/
skip |
• |
• |
• |
| 7-Day
Control |
|
|
|
|
|
|
|
|
|
|
| 365-Day
Calendar |
|
|
|
|
|
|
|
|
• |
• |
|
Holidays:
Single
Durations
|
|
|
|
|
|
|
|
|
|
|
| Time
Events |
16 |
24 |
7 |
288 |
36 |
48 |
48 |
12 |
4 |
4 |
| Manual
Toggle Override |
• |
• |
• |
• |
• |
|
• |
|
• |
• |
| Timed
Override |
|
|
|
|
|
|
|
• |
|
|
| Time-of-Day
Scheduling |
• |
|
• |
• |
|
• |
• |
|
• |
• |
| Time
Based Duty Cycling** |
|
|
|
|
|
|
|
|
|
|
| Sensor
Control |
|
|
|
|
|
|
|
|
|
|
AstroDial
|
|
|
|
|
|
|
|
|
• |
• |
Momentary
Contact/
Duration per channel |
|
|
|
1-59
sec. |
|
|
1
sec.-3 min.
59 sec. |
|
|
|
| Number
of Channels |
1 |
1 |
|
1 |
1 |
|
1 |
1 |
1 |
2 |
| ELECTRICAL |
Available
Voltages
(Vac Op. 50/60 Hz) |
120,
208-277 |
120,
208-277 |
120,
208-277 |
100-120 |
120 |
|
120,
208-240,480 |
120,
208-240 |
120 |
120 |
| Number
of Inputs |
|
|
|
|
|
|
|
|
|
|
| Number
of Outputs |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
| Type
of Output |
SPDT,
SPST,
DPST |
SPST,
DPST |
SPDT,
SPST,
DPST |
SPDT |
SPDT |
SPDT,
DPST |
SPDT |
2
N0-1NC |
SPST |
SPST |
| RELAY
RATINGS |
| 24V
Model (Resistive) |
|
|
|
|
|
|
|
|
|
|
| 24V
Model (Inductive) |
|
|
|
|
|
|
|
|
|
|
| 120V
Model (Resistive) |
20A |
40A |
40A |
15A |
20A |
15A |
10A |
40A |
30A |
40A |
| 120V
Model (Inductive) |
|
20A |
20A |
15A |
|
|
|
|
30A |
|
| 120V
Model (Tungsten) |
5A |
40A |
40A |
|
|
|
|
|
8A |
|
| 120V
Model (Ballast) |
6A |
|
|
|
|
|
|
|
|
|
| 240V
Model (Resistive) |
20A |
40A |
40A |
|
|
10A |
5A |
40A |
|
40A |
| 240V
Model (Inductive) |
|
20A |
20A |
|
|
|
|
|
|
|
| 240V
Model (Tungsten) |
5A |
40A |
40A |
|
|
|
|
|
|
|
| 240V
Model (Ballast) |
6A |
|
|
|
|
|
|
|
|
20A |
| 277V
Model (Resistive) |
20A |
40A |
40A |
|
|
|
|
|
|
40A |
| 277V
Model (Inductive) |
20A |
20A |
20A |
|
|
|
|
|
|
|
| 277V
Model (Tungsten) |
5A |
40A |
|
|
|
|
|
|
|
|
| 277V
Model (Ballast) |
6A |
|
|
|
|
|
|
|
|
20A |
| Carry-Over |
7
days |
|
|
275
hrs. |
|
|
|
|
48
hrs. |
48
hrs. |
| Carry-Over
type |
capacitor |
|
|
9-volt
lithium |
|
|
|
|
capacitor |
capacitor |
| PHYSICAL |
Enclosure
(Indoor/Outdoor) |
indoor |
metal
indoor |
metal
indoor |
DIN |
|
|
plastic
in/out |
|
in/out |
in/out |
Height
in.
cm. |
|
8-1/2
21.6 |
8
20.3 |
|
|
|
|
|
9
22.9 |
9
22.9 |
Width
in.
cm. |
|
4-1/8
10.5 |
4-1/4
10.8 |
|
|
|
|
|
6-1/2
16.5 |
6-1/2
16.5 |
Depth
in.
cm. |
|
2-1/4
5.7 |
3
7.6 |
|
|
|
|
|
3-7/8
9.8 |
3-7/8
9.8 |
Shipping
Wgt. lb.
kg. |
2
0.9 |
2
0.9 |
2-1/2
1.1 |
1-1/8
0.5 |
|
|
1-1/2
0.7 |
|
2
0.9 |
2
0.9 |
|