Invensys


Invensys Controls Americas

 

 

 


Company History
News Highlights
Press Releases
Invensys Sites
Job Opportunities
Employee Login






EL71 & EL72 SERIES

QUAD CONTROLS

 

The EL71 and EL72 Series has It all. This two-relay series has single-handedly replaced up to 5 controls and has every feature an industrial, commercial or municipal application could possibly require. The EL71 and EL72 can be used as 24-hour, 7-day, 365-day controls with daylight savings time, leap year adjustment and selectable SunTracker™ controls. Y2K compatible, they are easy to program with each control allowing up to 128 ON or OFF events, 34 holidays and 32 sensor events. 

You will need Adobe Acrobat Reader to view the manuals. If you do not have this installed, you can download it from Adobe's web site.

FEATURES & BENEFITS

96-Hour Carryover, unique to Paragon, protects scheduled events from power interruptions via a capacitor-more reliable than batteries.

Resolution enhancements allow 4 user-defined duty cycle patterns; 4 user-defined durations are available from I second to 23 hours, 59 minutes, 59 seconds.

ON/OFF events can be controlled by temperature, light or other sensors.

Enabler switch allows an ON event to be selected without pre-programming the event.

Pecosoft.EL software and CIMI Adaptor (each sold separately) allow remote programmability.

User-friendly keypad and easy-to-read digital time display take the frustration out of programming.

Remote override allows immediate reaction to unexpected events without affecting pre-programming or visiting the clock site.

UL and CSA listed means quality and durability are built into every time control.

Title 24 certified.

ENVIRONMENTAL
Operating Temperature Range: -20°F (-29°C) to 140°F (60°C)
Operating Temperature Range -20°F (-29°C) to 140°F (60°C) Operating Humidity 0-95%RH non-condensing Models in NEMA 1 enclosure should be mounted indoors in an environment that is free of excessive contaminants such as oil, moisture and dirt. Models in NEMA 3R non-metallic enclosure are suitable for both indoor and outdoor use.

PHYSICAL
EL71
Enclosure: NEMA 1 drawn steel with lockable hasp
Weight: Approximately 2 lbs. (0.9 kg)
Dimensions:
  Width 4-1/4” (10.8 cm)
  Height 7-7/8” (20.0 cm)
  Depth 3” (7.6 cm)
Display Size 2-5/8” x 3/4” (6.7 cm x 1.9 cm)

EL72
Enclosure: NEMA 3R non-metallic, with Clear-View cover
Weight: Approximately 2-1/2 lbs. (1.1 kg)
Dimensions:
 Width 6-9/16” (16.7 cm)
Height 9” (22.9 cm)
Depth 3-7/8” (9.8 cm)
Display Size 2-5/8” x 3/4” (6.7cm x 1.9 cm)

HOW TO SPECIFY
How to Specify Installer shall furnish and install Paragon EL71 single-channel (or EL72, two-channel) Electronic Time Control. The control shall have 24-hour, 7-day, 365 day, or SunTracker™ capability with 128 events available. It shall also have 4 user-definable durations and duty cycle lengths plus automatic daylight savings time and leap year adjustments. Control shall have remote override capabilities (timed, toggle or enable type.) Control shall have keyboard override until overridden again or until next event is reached. It shall be capable of switching loads based on user-definable temperature and light levels with 32 events available. Control shall have momentary (latching relay) capability and shall have Astro features plus 30 definable holidays and 6 pre-programmed holidays. Control shall typically provide 96 hours of power outage carry-over without a battery. The digital time display shall be 3/4” in height. Clock format shall be selectable, allowing a choice of 12 hour (AM/PM) or 24 hour format. Control shall be capable of interfacing (sending and receiving data) with a personal computer. Wiring terminals shall have the capability to accommodate #16 to #10 AWG wire. Control shall be housed in a NEMA 1, lockable steel enclosure or a NEMA 3R enclosure with Clear-View cover and shall be lockable to guard against vandalism or tampering.

ELECTRICAL SPECIFICATIONS

Model No.

Channels

Voltage


EL71/120

Single Channel

120 Vac

EL71/208-240

Single Channel

208-240 Vac

EL71/277

Single Channel

277 Vac

EL71PC/120

Single Channel

120 Vac

EL71PC/208-240

Single Channel

208-240 Vac

EL71PC/277

Single Channel

277 Vac

EL72/120

Two Channel

120 Vac

EL72/208-240

Two Channel

208-240 Vac

EL72/277

Two Channel

277 Vac

EL72PC/120

Two Channel

120 Vac

EL72PC/208-240

Two Channel

208-240 Vac

EL72PC/277

Two Channel

277 Vac

Note: PC suffix designates NEMA 3R non-metallic enclosure with Clear-View cover. All other models supplied in a NEMA 1 metal enclosure.

Frequency 50/60 Hz
Power Consumption 4 VA Max
Wiring Terminals  Power input and relay contact terminals can accommodate 10-16 AWG.
Sensor/override input terminals can accommodate 14-22 AWG UL Listed, CSA Certified, and comply with FCC, part 15 rules.
Power Outage Carry-Over (No battery needed)
The program and time-of-day are maintained during a power outage for a minimum of 7 days. A built-in, special capacitor eliminates the inconvenience of battery replacement.

 

Normally open contacts:
20 amp resistive or inductive at 120-277 Vac
1 Hp at 120 Vac
2 Hp at 208-277 Vac
5 amp tungsten at 120-240 Vac
20 amp ballast at 120 Vac
10 amp ballast at 208-277 Vac
470 VA at 120-240 Vac

Normally closed contacts:
10 amp resistive or inductive at 120-277 Vac
1/4 Hp at 120 Vac
1/2 Hp at 208-277 Vac
3 amp ballast at 120-277 Vac
275 VA at 120-240 Vac

 
TYPICAL WIRING DIAGRAMS
 


EL71 - Single Channel Control (Switching 2 loads with identical schedules)


(Switching both sides of line)


Typical Wiring Diagram for Controlling Latching Relays
(Momentary Contacts)


EL71 - Two Channel Control

 

CONTROL LAYOUT

Program Header Menu
TIME
CONF
ASTR
EVNT
INPT
EVNT SENS
HOL

Sensor Connection:
1. red
2. yellow
3. black
External Override: use 1+2
NOTE: It is recommended that shielded cable be used for sensor and override input wiring. The shield should be tied to earth ground at the control.

TEMPERATURE SENSORS AND LIGHT SENSOR

1.red(5V)
2.yellow (Signal)
3.black (GND)

To the EL Series time Control:
V+     red (5V)
SIG    yellow (Signal)
COM  black (GND)

 

TEMPERATURE SENSORS AND LIGHT SENSOR
 

Model No.

Description

Wiring Diagram

 

TS3-SAT

Solid-state temperature sensor for indoor use designed to interface directly with the EL71 and EL72. Operating temperature -40°F to l40°F (-40°C to 60°C). resolution 1.5F (1C). Dimensions: 4.5"H k 2.75"W x 1.25"D.

See Above

[Image]

TS3-OAT

Solid-state temperature sensor, sealed for outdoor use, designed to interface directly with the EL71 and EL72. Operating temperature -40°F to 167°F (-40°C to 75°C), resolution 1.5F (1C). Dimensions: 6.25"H x 1.25"W x 4"D. This sensor comes complete with a 3.5"D x 1.75"H non-metallic electrical box.

See Above

[Image]

LS-R

Solid-state light sensor designed to interface directly with the EL71 and EL72. It provides a relative light level to the control (0-88 L). The light sensor's range (0-300 foot candles) is adjustable to accommodate a wide variety of light sensing requirements. Dimensions: 2.5"L x l.28"D. (Electrical box not included.)

See Above

[Image]

 

 

 

Go to top

© Copyright 1999-2006 Invensys Controls. All rights reserved.
Privacy PolicyLegal Information