| The
choice is yours-the EL7100 and EL7200 Series can be used as
24-hour, 7-day or 365-day/full-year controls. Easily installed,
this one and two-channel series is the economical, user-friendly
solution for industrial, commercial and municipal applications.
This programmable series manages 128 ON/OFF events, 90 definable
holidays, 6 pre-programmed holidays, plus daylight savings time
adjustments.
|

You
will need Adobe
Acrobat Reader to view the manuals. If you do not have
this installed, you can download it from Adobe's
web site.
|
FEATURES
& BENEFITS
 |
Easy-to-use
keypad and clearly visible, digital time display take the
frustration out of programming. |
 |
96-Hour
Carryover, unique to Paragon, protects scheduled events from
power interruptions via a capacitor-more reliable than
batteries. |
 |
Momentary
Option (7200 Series only) can be configured for either
maintained or momentary operation in conjunction with
latching relays. |
|
 |
Latching
Relay (7200 Series only) is the most sophisticated lighting
contactor available because its easier to install and
more energy efficient. Y2K compatible. |
 |
UL
and CSA listed means quality and durability are built into
every time control. |
 |
Title
24 certified. |
|
ENVIRONMENTAL
Operating Temperature
Range: -20°F (-29°C) to 140°F (60°C)
Operating Humidity:
0-90%RH non-condensing
Models in Nema 1 enclosure should be mounted indoors in an
environment that is free of excessive contaminants such as
oil, moisture and dirt. Models in NEMA 3R non-metallic
enclosure are suitable for both indoor and outdoor use.
PHYSICAL
NEMA 1 drawn
steel with lockable hasp.
Weight: Approximately 2 lbs. (0.9 kg)
Dimensions:
Width 4-1/4 (10.8 cm)
Height 8-1/8 (23.1 cm)
Depth 3 (7.6 cm)
Display Size: 2-5/8 x 3/4
NEMA 3R non-metallic, with Clear-View cover
Weight: Approximately 2-1/2 lbs. (1.1 kg)
Dimensions:
Width 6-9/16 (16.7 cm)
Height 9 (22.9 cm)
Depth 3-7/8 (9.8 cm)
Display Size: 2-5/8 x 3/4
HOW
TO SPECIFY
Installer shall
furnish and install Paragon EL7100 single-channel (or
EL7200, two-channel) Electronic Time Control. The control
shall have 24-hour, 7-day or 365 day capability with 128
events available. It shall also have automatic daylight
savings time and leap year adjustments. Control shall have
keyboard override until overridden again or until next event
is reached. Control shall have momentary (latching relay)
capability plus 90 definable holidays and 6 pre-programmed
holidays. Control shall typically provide 96 hours of power
outage carry-over without a battery. The digital time
display shall be 3/4 in height. Clock format shall be
selectable, allowing a choice of 12 hour (AM/PM) or 24 hour
format. Wiring terminals shall have the capability to
accommodate #16 to #10 AWG wire. Control shall be housed in
a NEMA 1, lockable steel enclosure or a NEMA 3R enclosure
with Clear-View cover and shall be lockable to guard against
vandalism or tampering.
|
ELECTRICAL
SPECIFICATIONS
| Model
No. |
Channels |
Voltage |
|
| EL7100/120 |
Single
Channel |
120
Vac
|
| EL7100/208-240 |
Single
Channel |
208-240
Vac
|
| EL7100PC/120 |
Single
Channel |
120
Vac
|
| EL7100PC/208-240 |
Single
Channel |
208-240
Vac
|
| EL7200/120 |
Two Channel |
120
Vac
|
| EL7200/208-240 |
Two Channel |
208-240
Vac
|
| EL7200PC/120 |
Two Channel |
120
Vac
|
| EL7200PC/208-240 |
Two Channel |
208-240
Vac
|
|
|
|
Frequency: 50/60
Hz
Power Consumption: 4 VA Max.
Wiring Terminals: Power input and relay contact
terminals can accommodate 10-16 AWG.
UL Listed and CSA Certified.
Power Outage Carry-Over:
The program and time-of-day are maintained during a power
outage for typically 96 hours. A built-in capacitor
eliminates the inconvenience of battery replacement.
Output Switch Ratings: EL7100One SPDT relay with isolated
(dry) contacts rated as follows: EL7200Two SPDT relays
with isolated (dry) contacts rated as follows:
Normally
open contacts:
20 amp resistive or inductive at 120-277 Vac
1 Hp at 120 Vac
2 Hp at 208-277 Vac
5 amp tungsten at 120-240 Vac
20 amp ballast at 120 Vac
10 amp ballast at 208-277 Vac
470 VA at 120-240 Vac |
Normally
closed contacts:
10 amp resistive or inductive at 120-277 Vac
1/4 Hp at 120 Vac
1/2 Hp at 208-277 Vac
3 amp ballast at 120-277 Vac
275 VA at 120-240 Vac |
|