Paragon’s EC7000
Series is a 7-day control that allows the flexibility of a
different time schedule every day of the week. This digital
electronic, single-channel control series allows 16 events
to be programmed to accommodate any time-of-day schedule,
and allows days to be skipped. Available in NEMA 3R or NEMA
1 to meet the needs of any application, contractors will
appreciate this series’ ease of installation.
|

You
will need Adobe
Acrobat Reader to view the manuals. If you do not have
this installed, you can download it from Adobe's
web site.
|
FEATURES
& BENEFITS
 |
Resolution
enhanced with a 1 to 59-second programmable
duration. (EC7001) |
 |
User-friendly
control is easy-to-program with just four keys and a
large, easily-read digital display. |
|
 |
7-Day
Carryover, unique to Paragon, protects scheduled
events from power interruptions via a capacitor-more
reliable than batteries. |
 |
UL and CSA
listed means quality and durability are built into
every time control. |
 |
Title 24
Certified. |
|
ENVIRONMENTAL
Operating Temperature
Range -40°F to +140°F
Operating Humidity 0-95% non-condensing
EC7000, EC7001 and EC7004 should be mounted indoors in an
environment that is free from excessive contaminants such as
oil, moisture and dirt. Models with PC suffix are suitable
for both indoor and outdoor use.
PHYSICAL
EC7000, EC7001, EC7004
Case NEMA 1 drawn steel enclosure with lockable hasp.
Weight Approximately 2 lbs. (0.9 kg)
Dimensions:
Width 4-1/4” (10.8 cm)
Height 8-1/8” (23.1 cm)
Depth 3” (7.6 cm)
Display Size 1-3/4” x 11/16”
EL7000PC, EC7005PC
(PC suffix designates non-metallic enclosure with Clear-View
cover)
Case NEMA 3R Non-Metallic Enclosure
Weight Approximately 2-1/2 lbs. (1.1 kg)
Dimensions:
Width 6-9/16” (16.7 cm)
Height 8-1/8” (23.1 cm)
Depth 3-7/8” (9.8 cm)
Display Size 1-3/4” x 11/16”
HOW
TO SPECIFY
Installer shall
furnish and install Paragon EC7000, EC7001, EC7004 or EC7005
Electronic Time Control. The single-channel control shall
have 24-hour and 7-day programming capability with 16
setpoints available. Control shall have keyboard override
until overridden again or until next setpoint is reached.
Control shall provide 7 days power outage carry-over without
a battery. The digital time display shall be 11/16” in
height. Clock format shall be selectable, allowing a choice
of 12 hour (AM/PM) or 24 hour time format. An “ON” or
“OFF” display will indicate the current status of the
load control contacts. Wiring terminals shall have the
capability to accommodate #16 to #10 AWG wire. Control shall
be housed in a NEMA 1 lockable steel enclosure (EC7000,
EC7001 or EC7004) or a NEMA 3R lockable enclosure (EC7000PC
or EC7005PC) with a Clear-View cover, to guard against
vandalism or tampering.
|
ELECTRICAL
SPECIFICATIONS
| Model
No. |
Contact
Configuration |
Voltage |
|
| EC7000/24V |
SPDT |
24 Vac |
| EC7000/120V |
SPDT |
120 Vac |
| EC7000PC/120V-RT |
SPDT |
120 Vac |
| EC7000/208-277V |
SPDT |
208-277 Vac |
| EC7001PC/12VDC |
SPDT |
12 Vac |
| EC7001/24V |
SPDT |
24 Vac |
| EC7001/120V |
SPDT |
120 Vac |
| EC7001/208-277V |
SPDT |
208-277 Vac |
| EC7004/120V |
SPST |
120 Vac |
| EC7004/208-277V |
SPST |
208-277 Vac |
| EC7005PC/120,
208-240V |
DPST |
120, 208-240
Vac |
| EC7005PC/277V |
DPST |
277 Vac |
Frequency 50/60
Hz
Power Consumption 4 VA Max.
Wiring Terminals Accommodate #16 to #10 AWG wire.
UL Listed, CSA Certified, and comply with FCC rules.
(12 Volt and 24 Volt models are neither UL Listed nor CSA
Certified.) RT designates retail packaging.
Power Outage Carry-Over
The program and time-of-day are maintained during a power
outage for a minimum of 7 days. A built-in, special
capacitor eliminates the inconvenience of battery
replacement. Output Switch Ratings
Model
EC7000 & EC7001
Normally open contacts:
20 amp resistive (10 amp CSA) at 24-240 Vac
1 Hp (1/2 Hp CSA) at 120 Vac, 2 Hp (1 Hp CSA) at 240
Vac
5 amp tungsten at 120-240 Vac
6 amp ballast at 120-277 Vac |
Normally
closed contacts:
10 amp resistive at 12-28 Vac
Model
EC7004
Normally open contacts:
30 amp resistive at 24-240 Vac (UL) 30 amp resistive
at 120 Vac (CSA)
10 amp resistive at 240 Vac (CSA)
1 Hp at 120 Vac, 2 Hp at 240 Vac
5 amp tungsten at 120-240 Vac
6 amp ballast at 120-277 Vac
|
Normally
closed contacts:
10 amp resistive at 24-240 Vac
1/4 Hp at 120 Vac, 1/2 Hp at 240 Vac
3 amp tungsten at 120-240 Vac
3 amp ballast at 120-277 Vac |
Model
EC7005PC
Normally open contacts:
30 amp resistive at 120-277 Vac
1 Hp at 120 Vac, 3 Hp at 240 Vac
15 amp tungsten at 120-277 Vac (UL)
5 amp tungsten at 240 Vac (CSA)
20 amp ballast at 120 Vac, 10 amp at 277 Vac |
(12 Vac
Model)
Normally open contacts:
20 amp resistive at 12-28 Vdc |
|
|