DOUBLE DUTY CLOCKS

Paragon’s EC7000 Series is a 7-day control that allows the flexibility of a different time schedule every day of the week. This digital electronic, single-channel control series allows 16 events to be programmed to accommodate any time-of-day schedule, and allows days to be skipped. Available in NEMA 3R or NEMA 1 to meet the needs of any application, contractors will appreciate this series’ ease of installation.

Download Sell Sheet

Download Manual For EC7000/EC7004/EC7005 Models

Download Manual For EC7001 Model

You will need Adobe Acrobat Reader to view the manuals. If you do not have this installed, you can download it from Adobe's web site.

FEATURES & BENEFITS

Resolution enhanced with a 1 to 59-second programmable duration. (EC7001)
User-friendly control is easy-to-program with just four keys and a large, easily-read digital display.
7-Day Carryover, unique to Paragon, protects scheduled events from power interruptions via a capacitor-more reliable than batteries.
UL and CSA listed means quality and durability are built into every time control.
Title 24 Certified.
ENVIRONMENTAL
Operating Temperature Range -40°F to +140°F
Operating Humidity 0-95% non-condensing
EC7000, EC7001 and EC7004 should be mounted indoors in an environment that is free from excessive contaminants such as oil, moisture and dirt. Models with PC suffix are suitable for both indoor and outdoor use.

PHYSICAL
EC7000, EC7001, EC7004

Case NEMA 1 drawn steel enclosure with lockable hasp.
Weight Approximately 2 lbs. (0.9 kg)
Dimensions:
  Width 4-1/4” (10.8 cm)
  Height 8-1/8” (23.1 cm)
  Depth 3” (7.6 cm)
Display Size 1-3/4” x 11/16”

EL7000PC, EC7005PC
(PC suffix designates non-metallic enclosure with Clear-View cover)
Case NEMA 3R Non-Metallic Enclosure
Weight Approximately 2-1/2 lbs. (1.1 kg)
Dimensions:
  Width 6-9/16” (16.7 cm)
  Height 8-1/8” (23.1 cm)
  Depth 3-7/8” (9.8 cm)
Display Size 1-3/4” x 11/16”

HOW TO SPECIFY
Installer shall furnish and install Paragon EC7000, EC7001, EC7004 or EC7005 Electronic Time Control. The single-channel control shall have 24-hour and 7-day programming capability with 16 setpoints available. Control shall have keyboard override until overridden again or until next setpoint is reached. Control shall provide 7 days power outage carry-over without a battery. The digital time display shall be 11/16” in height. Clock format shall be selectable, allowing a choice of 12 hour (AM/PM) or 24 hour time format. An “ON” or “OFF” display will indicate the current status of the load control contacts. Wiring terminals shall have the capability to accommodate #16 to #10 AWG wire. Control shall be housed in a NEMA 1 lockable steel enclosure (EC7000, EC7001 or EC7004) or a NEMA 3R lockable enclosure (EC7000PC or EC7005PC) with a Clear-View cover, to guard against vandalism or tampering.

ELECTRICAL SPECIFICATIONS
Model No. Contact
Configuration
Voltage

EC7000/24V SPDT 24 Vac
EC7000/120V SPDT 120 Vac
EC7000PC/120V-RT SPDT 120 Vac
EC7000/208-277V SPDT 208-277 Vac
EC7001PC/12VDC SPDT 12 Vac
EC7001/24V SPDT 24 Vac
EC7001/120V SPDT 120 Vac
EC7001/208-277V SPDT 208-277 Vac
EC7004/120V SPST 120 Vac
EC7004/208-277V SPST 208-277 Vac
EC7005PC/120, 208-240V DPST 120, 208-240 Vac
EC7005PC/277V DPST 277 Vac

Frequency 50/60 Hz
Power Consumption 4 VA Max.
Wiring Terminals Accommodate #16 to #10 AWG wire.
UL Listed, CSA Certified, and comply with FCC rules.
(12 Volt and 24 Volt models are neither UL Listed nor CSA Certified.) RT designates retail packaging.
Power Outage Carry-Over
The program and time-of-day are maintained during a power outage for a minimum of 7 days. A built-in, special capacitor eliminates the inconvenience of battery replacement. Output Switch Ratings
Model EC7000 & EC7001
Normally open contacts:

20 amp resistive (10 amp CSA) at 24-240 Vac
1 Hp (1/2 Hp CSA) at 120 Vac, 2 Hp (1 Hp CSA) at 240 Vac
5 amp tungsten at 120-240 Vac
6 amp ballast at 120-277 Vac
Normally closed contacts:
10 amp resistive at 12-28 Vac

Model EC7004
Normally open contacts:

30 amp resistive at 24-240 Vac (UL) 30 amp resistive at 120 Vac (CSA)
10 amp resistive at 240 Vac (CSA)
1 Hp at 120 Vac, 2 Hp at 240 Vac
5 amp tungsten at 120-240 Vac
6 amp ballast at 120-277 Vac

Normally closed contacts:
10 amp resistive at 24-240 Vac
1/4 Hp at 120 Vac, 1/2 Hp at 240 Vac
3 amp tungsten at 120-240 Vac
3 amp ballast at 120-277 Vac
Model EC7005PC
Normally open contacts:

30 amp resistive at 120-277 Vac
1 Hp at 120 Vac, 3 Hp at 240 Vac
15 amp tungsten at 120-277 Vac (UL)
5 amp tungsten at 240 Vac (CSA)
20 amp ballast at 120 Vac, 10 amp at 277 Vac
(12 Vac Model)
Normally open contacts:

20 amp resistive at 12-28 Vdc

 
TYPICAL WIRING DIAGRAMS
 

Diagram #1 - SPDT

 Diagram #2 - SPDT

Diagram #3 - SPST

Diagram #4 - DPST
 

Go to top